ISO 11507-2007标准介绍

DIN EN ISO 11507:2007发行信息

标准号:DIN EN ISO 11507:2007

发行日期:2007年5月01日

发行方:STANDARD by DIN-adopted European-adopted ISO Standard

中文名:涂料和清漆.涂层暴露于人工风蚀.暴露于荧光紫外灯和水

英文名:Paints and varnishes - Exposure of coatings to artificial weathering - Exposure to fluorescent UV lamps and water (ISO 11507:2007); German version EN ISO 11507:2007

DIN EN ISO 11507

DIN EN ISO 11507:2007适用范围

本国际标准规定了在包括荧光紫外灯和冷凝或水喷雾在内的仪器中暴露于人工风化的油漆涂层的暴露条件。通过所选参数的对比试验,分别评价了风化作用的影响。注:荧光灯产生的紫外线仅模拟自然阳光紫外线区域的一部分,因此,试样受到光谱的一小部分破坏。由于与太阳光相比,这种紫外线灯发出的光缺乏可见光和红外线能量,因此试件的加热方式没有达到实际使用时周围空气的温度以上。

This International Standard specifies exposure conditions for paint coatings exposed to artificial weathering in apparatus including fluorescent UV lamps and condensation or water spray. The effects of weathering are evaluated separately by comparative testing of chosen parameters. NOTE The ultraviolet light produced by fluorescent lamps simulates only part of the UV region of natural sunlight and, consequently, the test pieces are subjected to a small but destructive portion of the spectrum. Due to the lack of visible and infra-red energy in the light from such UV lamps compared to sunlight, the test pieces are not heated above the temperature of the surrounding air in the way in which they would be in practical use.

符合DIN EN ISO 11507:2007的紫外老化试验箱

点击图片查看产品,或电话咨询18566398802

美国Q-LAB品牌 QUV系列紫外老化试验箱

紫外光加速老化试验机


1 Scope

This International Standard specifies exposure conditions for paint coatings exposed to artificial weathering inapparatus including fluorescent UV lamps and condensation or water spray. The effects of weathering areevaluated separately by comparative testing of chosen parameters.

NOTE The ultraviolet light produced by fluorescent lamps simulates only part of the UV region of natural sunlight and,consequently, the test pieces are subjected to a small but destructive portion of the spectrum.

Due to the lack of visible and infra-red energy in the light from such UV lamps compared to sunlight, the testpieces are not heated above the temperature of the surrounding air in the way in which they would be inpractical use.

2 Normative references

The following referenced documents are indispensable for the application of this document. For datedreferences, only the edition cited applies. For undated references, the latest edition of the referenceddocument (including any amendments) applies.

ISO 1513, Paints and varnishes — Examination and preparation of samples for testing

ISO 1514, Paints and varnishes — Standard panels for testing

ISO 2808, Paints and varnishes — Determination of film thickness

ISO 3696: 1987, Water for analytical laboratory use — Specification and test methods